Spine · 2009 · 33 citations · 16 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryDiagnostic ImagingDiagnostic RadiologyOrthopedicsImaging AssessmentImaging InterpretationLumbar Spine SurgeryMusculoskeletal AssessmentOsteoarthritisSpinal AssessmentFacet Joint AssessmentFacet Joint OsteoarthritisInter-rater AgreementInter-rater ReliabilityKappa StatisticLumbar Spine ImagingMagnetic Resonance Imaging GradingRater Agreement
In Brief Study Design. Prospective inter-rater and intrarater reliability analysis. Objective. To compare the inter-rater and intrarater reliability of magnetic resonance imaging (MRI) and computed tomography (CT) for grading of facet arthropathy as well as determining whether there is a contraindication to total disc replacement (TDR). Summary of Background Data. Several classifications attempted to evaluate lumbar facet joints and their degree of arthropathy. The Fujiwara-MRI and Pathrea–CT classifications remain the most commonly used. Methods. A total of 10 fellowship-trained orthopedic spine surgeons and 3 orthopedic spine fellows evaluated 50 levels from L3–L4 through L5–S1 on parallel axial MRI (T1 and T2) and CT images. The degree of osteoarthritis was graded on a 4-point scale (Fujiwara-MRI and Pathrea-CT). Surgeons evaluated whether the degree of facet disease represented a contraindication to TDR. Grading was performed during 2 sessions. Weighted kappa statistics were used to describe inter- and intraobserver agreement. Results. The inter-rater reliability for MRI was 0.21 and 0.07 (fair to slight) among attendings and fellows, respectively. inter-rater reliability for CT was 0.33 and 0.27 (fair), respectively. The mean intrarater reliability for MRI was fair, 0.36 (attendings) and 0.26 (fellows). The mean intrarater reliability for CT was moderate, 0.52 (attendings) and 0.51 (fellows). For possible TDR contraindication, the inter-rater reliability for MRI was 0.22 and 0.01 (fair to slight) among attendings and fellows, respectively. Inter-rater reliability for CT was 0.33 and 0.45 (fair), respectively. The mean intrarater reliability for MRI was fair, 0.36 (attendings) and 0.26 (fellows). The mean intrarater reliability for CT was moderate, 0.52 (attendings) and 0.51 (fellows). Conclusion. The current grading system for facet arthropathy has only fair agreement. CT is slightly more reliable for grading. Intrarater reliability was only fair for MRI and moderate for CT. Only limited agreement existed between surgeons as to the extent of facet disease that would pose as a contraindication for TDR. This study analyzed the facet arthropathy grading intrarater and inter-rater reliability for computed tomography and magnetic resonance imaging. A total of 10 spine surgeons and 3 spine fellows evaluated 50 lumbar levels. The current grading system has only fair agreement. Computed tomography is slightly more reliable. Limited agreement existed as to which facet is a contraindication for total disc replacement.
16
The Measurement of Observer Agreement for Categorical Data
J. Richard Landis, Gary G. Koch · Biometrics · 1977 · 78.9K citations · Full text
Radiological Assessment of Osteo-Arthrosis
Jan Kellgren, J. S. Lawrence · Annals of the Rheumatic Diseases · 1957 · 12.4K citations · Full text
A Study of Computer-Assisted Tomography
Sam W. Wiesel, Nicholas F. Tsourmas, Henry L. Feffer et al. · Spine · 1984 · 721 citations
MR imaging and CT in osteoarthritis of the lumbar facet joints
Dominik Weishaupt, Marco Zanetti, Norbert Boos et al. · Skeletal Radiology · 1999 · 541 citations