Journal of the Optical Society of America B · 2007 · 38 citations · 19 references
EngineeringElectrical EngineeringOpticsPhotonicsSensorsLaser OpticsMagnetic SensorsOptical SensingOptical SensorsOptical SourcesCoherent Population TrappingExcitationFrequency Comb GenerationHigh-sensitivity MagnetometersMagnetometer InstrumentationMagnetometer MeasurementsMagnetometersSensitivity
An automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on coherent population trapping (CPT) produced by a multifrequency excitation. CPT resonance is observed when a frequency comb, generated by diode laser current modulation, excites Cs atoms confined in a π/4×(2.5)2×1 cm3, 2 TorrN2 buffered cell. A fully optical sensor is connected through an optical fiber to the laser head allowing for truly remote sensing and minimization of the field perturbation. A detailed analysis of the CPT resonance parameters as a function of the optical detuning has been made in order to get high sensitivity measurements. The magnetic field monitoring performances and the best sensitivity obtained in a balanced differential configuration of the sensor are presented.
19
A subfemtotesla multichannel atomic magnetometer
I. K. Kominis, T. W. Kornack, Joel C. Allred et al. · Nature · 2003 · 1.6K citations
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
J. C. Allred, ROBERT LYMAN, T. W. Kornack et al. · Physical Review Letters · 2002 · 1K citations