Radiology · 2003 · 26 citations · 17 references
MedicineNephrologyRadiologyDiagnostic ImagingDiagnostic RadiologyHemodialysisDialysis AccessDialysis Vascular AccessIntravascular ImagingVascular AccessVascular ImagingVenous AccessContrast-enhanced AngiographyContrast-enhanced Magnetic Resonance AngiographyFalse Positive Angiographic FindingsFalse Positive FindingsMagnetic Resonance AngiographyRenal AngiographySubclavian Artery AnatomyVascular Access Evaluation
Ten patients with failing hemodialysis access underwent contrast material-enhanced magnetic resonance (MR) angiography within 7 days before digital subtraction angiography (DSA). MR angiography was performed at 1.5 T by using a multistation multiinjection three-dimensional technique, and contrast material was injected via intravenous cannula. In all patients, MR angiographic images displayed the complete arterial inflow tract from the subclavian artery and access proper. The complete venous outflow tract up to the superior caval vein could be evaluated in all but one patient. DSA showed hemodynamically significant stenoses in 13 segments. MR angiography depicted all 13 stenoses and two false-positive findings, resulting in sensitivity of 100% and specificity of 94%.
17
Gadolinium-enhanced MR aortography.
Martin R. Prince · Radiology · 1994 · 895 citations
Dialysis access grafts: anatomic location of venous stenosis and results of angioplasty.
R Y Kanterman, Thomas M. Vesely, T K Pilgram et al. · Radiology · 1995 · 369 citations
Medicine, Nephrology, Surgery +13
Graft flow as a predictor of thrombosis in hemodialysis grafts
Peter J. Bosman, F. T. J. Boereboom, B.C. Eikelboom et al. · Kidney International · 1998 · 85 citations
Medicine, Hematology, Nephrology +14