Journal of Periodontology · 2010 · 41 citations · 41 references
Natural SciencesBioengineeringBiomedical EngineeringBiomaterialsBiomedical OpticsBiophotonicsBioceramicsBiomedical Laser ApplicationsLaser-tissue InteractionOsteoblast BiologyOsteoblast FunctionSurface Modification Of ImplantsEr:yag Laser DecontaminationLaser Irradiation ParametersLaser Surface TreatmentLaser-assisted Implant Surface CleaningLasersOsteoblastic Activity AssessmentOsteoblastic Lineage CellsOsteocalcin Biology
BACKGROUND: Laser light has been proposed as a tool to decontaminate the surface of endosseous implants. The effects of this maneuver on the interactions between cells and surface, however, are poorly known. The goal of the present study is to investigate osteoblast growth and differentiation on three commercially available surfaces untreated or after irradiation by erbium-doped:yttrium, aluminum, and garnet (Er:YAG) laser at two levels: 150 and 200 mJ/pulse at 10 Hz. METHODS: Human osteoblastic Saos-2 cells were plated on machined, sandblasted and acid-etched titanium, or titanium plasma-sprayed disks. The effects of lasing were observed with a scanning electronic microscope, and cell viability was measured by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay. Moreover, we measured the production of the osteoblast-specific protein osteocalcin and of osteoprotegerin in the supernatants by immunoenzymatic assays. RESULTS: Although no visible changes were observed on machined or titanium plasma-sprayed disk samples at the tested levels, titanium peaks on sandblasted and acid-etched titanium disks appeared fused as a consequence of laser irradiation. Interestingly, cell proliferation was slower on irradiated titanium at both intensities on all the surfaces. Cell differentiation, as assessed by osteocalcin production, was generally unaffected by laser treatment, whereas the production of osteoprotegerin was decreased on all the surfaces irradiated at the intensity of 200 mJ/10Hz. CONCLUSIONS: These results indicate that Er:YAG laser at energy levels used in this study can alter the surface profile of titanium implants and these changes may negatively affect the viability and the activity of osteoblastic cells. Therefore, Er:YAG lasers should be used with caution on titanium surfaces.
41
Hisataka Yasuda, Nobuyuki Shima, N. Nakagawa et al. · Proceedings of the National Academy of Sciences · 1998 · 4.3K citations
Effect of material characteristics and/or surface topography on biofilm development
Wim Teughels, Nele Van Assche, I. Sliepen et al. · Clinical Oral Implants Research · 2006 · 1.3K citations · Full text
Enhanced Bone Apposition to a Chemically Modified SLA Titanium Surface
Daniel Buser, Nina Broggini, Marco Wieland et al. · Journal of Dental Research · 2004 · 1.2K citations
Differential regulation of osteoblasts by substrate microstructural features
O. Zinger, Gang Zhao, Z. Schwartz et al. · Biomaterials · 2004 · 352 citations