Journal of Cardiovascular Medicine · 2011 · 44 citations · 16 references
MedicineCardiologyInternal MedicineClinical CardiologyCritical Care CardiologyHemodynamic ManagementCardiac AssessmentCardiac CatheterizationCardiovascular AssessmentCardiovascular MonitoringHeart FailureHemodynamicsArterial Blood Pressure Waveform AnalysisCardiac OutputHeart Failure Hemodynamic EvaluationHemodynamic MonitoringHemodynamic Monitoring ModalitiesSwan-ganz CatheterizationVascular ResistanceVentricular Ejection Fraction Assessment
AIM: Measurement of haemodynamic parameters using a Swan-Ganz catheter is of clinical importance in patients with advanced heart failure; however, its applicability is limited due to its invasiveness. The aim of the study was to estimate the concordance between invasive and non-invasive measurements of haemodynamic parameters in patients with advanced heart failure. METHODS AND RESULTS: We examined 25 patients with advanced heart failure (20 men, age: 64 ± 11 years, New York Heart Association class III/IV: 88/12%, left ventricular ejection fraction: 37 ± 20%), 13 (52%) demonstrated decompensated heart failure. Resting haemodynamic parameters were measured simultaneously using two methods: an invasive Swan-Ganz catheterization and a thermodilution technique; and a non-invasive recording using a device for finger arterial pressure waveform analysis. The following parameters were analysed: stroke volume (SV, ml), cardiac output (CO, l/min) and systemic vascular resistance (SVR, dyne × s/cm⁵). The concordance between these two methods was assessed using the variability coefficient calculated according to a Bland-Altman method. Comparing the invasive and non-invasive measures, variability coefficients were: 13, 18 and 11% for SV, SVR and CO, respectively. Similar variability coefficients were obtained when invasive and non-invasive measurements were compared in prespecified subgroups of patients, distinguished based on the presence of decompensation, atrial fibrillation and values of SBP. CONCLUSIONS: Evaluation of haemodynamic parameters using a non-invasive method based on a pressure pulse contour model reveals an adequate concordance with the measures obtained using an invasive approach. Our results suggest that a non-invasive method for haemodynamic monitoring could be applied in clinical practice in patients with advanced heart failure.
16
A H BECKETT, M ROWLAND, P TURNER · The Lancet · 1965 · 16.9K citations
Recommendations for Blood Pressure Measurement in Humans and Experimental Animals
Thomas G. Pickering, John E. Hall, Lawrence J. Appel et al. · Hypertension · 2004 · 2.1K citations · Full text
Evaluation Study of Congestive Heart Failure and Pulmonary Artery Catheterization Effectiveness
Cynthia Binanay, Robert M. Califf, Vic Hasselblad et al. · JAMA · 2005 · 1.5K citations · Full text