Journal of Biophotonics · 2009 · 63 citations · 31 references
EngineeringBiomedical EngineeringDermatologyBiomedical ImagingBiomedical OpticsBiophotonicsLight-tissue InteractionOptical Coherence TomographyOptical TomographyPermeability AssessmentTissue Optical PropertiesTissue OpticsDrug Diffusion KineticsDrug Permeation Through SkinGlucose SensingMolecular DiffusionOptical Characterization Of Biological TissuePermeability MappingPermeability MeasurementTime-domain Optical Coherence Tomography
Topical trans-dermal delivery of drugs has proven to be a promising route for treatment of many dermatological diseases. The aim of this study is to monitor and quantify the permeability rate of glucose solutions in rhesus monkey skin noninvasively in vivo as a primate model for drug diffusion. A time-domain Optical Coherence Tomography (OCT) system was used to image the diffusion of glucose in the skin of anesthetized monkeys for which the permeability rate was calculated. From 5 experiments on 4 different monkeys, the permeability for glucose-20% was found to be (4.41 +/- 0.28) 10(-6) cm/sec. The results suggest that OCT might be utilized for the noninvasive study of molecular diffusion in the multilayered biological tissues in vivo.
31
David Huang, Eric A. Swanson, Charles P. Lin et al. · Science · 1991 · 13.7K citations
Handbook of Chemistry and Physics
Journal of AOAC INTERNATIONAL · 1937 · 4.8K citations
Mammographic densities and breast cancer risk.
N F Boyd, Gina Lockwood, J W Byng et al. · PubMed · 1998 · 810 citations
Diffusion of high molecular weight compounds through sclera.
Jayakrishna Ambati, Christina Canakis, Joan W. Miller et al. · PubMed · 2000 · 360 citations
Pharmacy, Biochemistry, Biomaterials +13