Performance Analysis of PV Systems on the Water

Yuzuru Ueda, Takemaro Sakurai, S. Tatebe, Akichika Itoh, Kosuke Kurokawa

EU PVSEC · 2008 · 47 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

Floating PV systems are developed and installed on the water surface of the “Aichi ike” balancing reservoir in Aichi, Japan. Floating systems are fixed by anchors and DC cables are connected to the inverter which is mounted on the ground. Systems are grid connected and those outputs are monitored every minute. PV module cooling system with intermittent watering is installed in one of the floating systems and performance is compared with the other systems. As a result, loss ratio due to the module temperature rise is reduced from 17.0 [%] to 7.4 [%] in August 2007. The cooling effect becomes smaller in winter but still has approximately 3 [%] improvements. This paper describes the overview and analysis result of the PV systems on the water.