Journal of international Conference on Electrical Machines and Systems · 2013 · 19 citations · 3 references
EngineeringElectrical EngineeringMechanical EngineeringElectric MachinesMachine DesignPower ElectronicsElectric MotorsPermanent Magnet MachinesPermanent MagnetsSurface MagnetismMaximum OutputMaximum Power OutputOperating VoltagePermanent Magnet Motor DesignPermanent Magnet MotorsPower FactorSurface Permanent Magnet MachinesSurface Permanent Magnet Synchronous Machines
In this paper, the authors designed a surface permanent magnet (SPM)-type vernier motor whose maximum output is more than 5.2 kW, whose power factor at 4 kW is more than 90%, and whose efficiency at 4 kW is 85% under the conditions that the operating voltage, frequency, and synchronous speed are 400 V, 50 Hz, and 100 min-1, respectively.
3