Review of Scientific Instruments · 2010 · 67 citations · 7 references
Natural SciencesNuclear EngineeringPhysicsNuclear PhysicsOpticsPlasma PhysicsFusion PlasmasHigh-temperature PlasmasPlasma DiagnosticsTokamak EngineeringBeam OpticsPlasma Density ProfilingThomson ScatteringTokamak Physics
To measure the electron temperature (T(e)) and electron density (n(e)) profiles in the Korean Superconducting Tokamak Advanced Research (KSTAR) device for the KSTAR third campaign (September 2010), we designed and installed a Thomson scattering system. The KSTAR Thomson scattering system is designed as a tangential Thomson scattering system and utilizes the N-, L-, and B-ports. The N-port is designed for the collection optics with a cassette system, the L-port is the laser input port, and the B-port is the location of the beam dump. In this paper, we will describe the final design of the KSTAR Thomson scattering system.
7
Measurement of the Electron Temperature by Thomson Scattering in Tokamak T3
N J Peacock, D.C. Robinson, M. Forrest et al. · Nature · 1969 · 256 citations
The Thomson scattering systems of the ASDEX upgrade tokamak
H. Murmann, S. Götsch, H. Röhr et al. · Review of Scientific Instruments · 1992 · 94 citations