Method to increase reliability in 5-level inverter
10
Citations
4
References
2003
Year
ReliabilityElectrical EngineeringReliability EngineeringBalanced OperationEngineering5-Level InverterCascaded 5-Level InverterPower Electronics ConverterSystems EngineeringCircuit ReliabilityPower InverterPower ElectronicsFaulty Cells
A method to operate a cascaded 5-level inverter with faulty cells is presented. The addition of a contactor and the displacement in the reference voltages allows for a balanced operation, increasing the reliability of the converter.