Medical Physics · 2015 · 48 citations · 27 references
MedicineCardiologyPediatricsClinical CardiologyInterventional CardiologyPediatric CardiologyPatient-specific DosimetryPediatric Interventional CardiologyPediatric Interventional RadiologyCumulative Dose AssessmentCumulative Dose EvaluationDose Calculations For ChildrenDose Estimation In ChildrenFluoroscopy Time AnalysisPatient Dose AssessmentPatient Dose MeasurementPediatric Dosimetry
PURPOSE: To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. METHODS: Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-area product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. RESULTS: Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for <1 yr; 213 for 1 to <5 yr; 82 for 5 to <10 yr; and 102 for 10 to <16 yr. The third quartile values obtained for DAP by diagnostic and therapeutic procedures and age range were 1.17 and 1.11 Gy cm2 for <1 yr; 1.74 and 1.90 Gy cm2 for 1 to <5 yr; 2.83 and 3.22 Gy cm2 for 5 to <10 yr; and 7.34 and 8.68 Gy cm2 for 10 to <16 yr, respectively. The third quartile value obtained for the DAP/body weight ratio for the full sample of procedures was 0.17 (Gy cm2/kg) for diagnostic and therapeutic procedures. CONCLUSIONS: The data presented in this paper are an initial attempt at establishing local DRLs in pediatric interventional cardiology, from a large sample of procedures for the standard age bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there may be large differences in child size. These DRLs were obtained at the largest pediatric hospital in Chile, with an active optimization program, and could be used by other hospitals in the Latin America region to compare their current patient dose values and determine whether corrective action is appropriate.
27
Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998
Dale L. Preston, Elaine Ron, Shoji Tokuoka et al. · Radiation Research · 2007 · 1.7K citations
Benefits and costs, an eternal balance
Adrian K. Dixon · Annals of the ICRP · 2007 · 1.4K citations
Radiation Protection in Medicine
Annals of the ICRP · 2007 · 625 citations
Patient-Specific Dose and Radiation Risk Estimation in Pediatric Cardiac Catheterization
Klaus Bacher, E. Bogaert, Régine Lapere et al. · Circulation · 2004 · 273 citations
Medicine, Cardiology, Pediatrics +17