High-sensitivity two-component measuring technique of inductances as applied to the investigation of magnetic after-effects

F. Walz

physica status solidi (a) · 1984 · 81 citations · 3 references

Concepts

Abstract

A versatile automatized measuring technique is developed with special respect to the investigation of magnetic after-effects (MAEs) occurring in ferro- and ferrimagnetic materials. The method is based on a voltage-controled LC-oscillator, the resonance conditions of which allow to determine quantitatively both components of coil-impedances. By various types of measurements performed on a series of different Fe samples it is demonstrated that the knowledge on both components may be helpful for the analysis of MAEs, particularly for a discrimination between different relaxation mechanisms. Ein vielseitiges, automatisches Meßverfahren zur Untersuchung der magnetischen Nachwirkung in ferro- und ferrimagnetischen Materialien wird weiterentwickelt und quantitativ geprüft. Grund-lage des Verfahrens ist ein spannungsgeregelter LC-Oszillator aus dessen Resonanzbedingungen die beiden Komponenten komplexer induktiver Widerstände mit großer Genauigkeit bestimmt werden können. Durch verschiedenartige Messungen an einer Reihe unterschiedlich vorbehandelter Eisen-Proben wird gezeigt, daß die Zeitabhángigkeit beider Komponenten fúr die Analyse magne-tischer Nachwirkungsmessungen wichtig sein kann, insbesondere zur Unterscheidung zwischen verschiedenen Nachwirkungsmechanismen.

References

3