Nuclear Science and Engineering · 2014 · 20 citations · 2 references
Natural SciencesNuclear EngineeringPhysicsNuclear PhysicsRadiation DetectionRadiation MeasurementNeutron DetectionNuclear Cross SectionsNuclear FissionDetector Dead TimeElement Sensitivity AnalysisInduced FissionMultiplicity CountingNeutron Multiplicity CountingNeutron-induced FissionSource-detector Spacing EffectsUncertainty Quantification In Neutronics
Simulations of neutron multiplicity measurements of a highly multiplicative plutonium sphere measured with a moderated array of 3He proportional counters have consistently overpredicted the mean and variance of the measured multiplicity distribution. In contrast, identical experiments using a 252Cf source have been accurately simulated. This paper outlines a sensitivity analysis of several key parameters that could account for the overprediction in the simulation of the plutonium sphere. Parameters that were analyzed include source-detector distance, detector dead time, variations in density and volume of the plutonium, and the value of for v̄ 239Pu-induced fission. Of these parameters, the only factor that accounted for the overprediction within reasonable bounds was a change in the value of the 239Pu v̄. The sensitivity analysis showed that a small change (1.14% reduction) in the value of v̄ dramatically improved the simulated results.
2