The data appear to support the use of a quantitative D-dimer assay as a first-line test in evaluation for pulmonary embolism when the clinical probability of the presence of pulmonary embolism is low or intermediate. The sensitivity and negative predictive value were 100% for these cases. More than 26% of CT angiographic examinations might have been avoided if the D-dimer assay had been used as a first-line test in the care of patients at low or intermediate risk. Because of the small sample size, the D-dimer assay is not recommended as a first-line test in the evaluation of patients at high risk.