British Journal of Radiology · 1972 · 17 citations · 6 references
EducationBiostatisticsBone MetabolismMeasurement InvarianceNeuromusculoskeletal AssessmentBone BiomechanicsBone Quantity AssessmentMeasurement PrecisionClinical Measurement ReliabilityCortical Bone AssessmentIntra-subject VariabilityMeasurementMetacarpal Anatomy
A single determination of the metacarpal cortical index can be considered accurate to within ±0·036, which is +10 per cent of the usual values of the cortical index in normal bone. Comparison of estimates of the over-all variation in the index (including observer variation) with estimates of the measurement variation indicates that much of over-all variability is due to the measuring process itself, and is therefore unavoidable. Improvement in reproducibility can be obtained by using the average of two independent determinations of the cortical index in place of a single assessment.
6
The radiological diagnosis of osteoporosis: A new approach
Ellis Barnett, B. E. C. Nordin · Clinical Radiology · 1960 · 743 citations
Elementary Medical Statistics.
Archives of Internal Medicine · 1952 · 144 citations
Observer error and measurements of the metacarpal
Peter Adams, Geraint Davies, P.M. Sweetnam · British Journal of Radiology · 1969 · 48 citations