Physical Review A · 1996 · 129 citations · 22 references
Natural SciencesPhysicsOpticsPhotonicsQuantum MechanicsLaser OpticsNonlinear OpticsOptical CoherencePhysical OpticsQuantum EntanglementCoherence FunctionsCoherence PropertiesCoherence TimeEntangled PhotonsEntangled StatesParametric Down-conversionSecond-order CoherenceWave Function Normalization
The second‑ and fourth‑order coherence functions are expressed as products of Gaussian functions of azimuthal and polar angles and time delay, whose widths determine six coherence and entanglement parameters. The authors use a multidimensional Gaussian approximation of the down‑conversion wave function to derive analytical expressions for second‑ and fourth‑order coherence functions, then experimentally confirm the predicted dependence on aperture mismatch using LiIO3 pumped by a 413 nm Kr⁺ laser. The coherence and entanglement parameters depend on pump waist, spectral width, and crystal length, leading to relations analogous to the van Cittert–Zernike theorem and Siegert relation, and the normalized photon coincidence rate drops sharply with aperture mismatch or misalignment. © 1996 The American Physical Society.
Using a multidimensional Gaussian approximation of the wave function for the signal and idler light generated by spontaneous parametric down-conversion, we derive analytical expressions for the second-order coherence function and the fourth-order coherence function (which is proportional to the signal-idler photon coincidence rate). The magnitudes of these functions are expressed as products of Gaussian functions of the azimuthal angles, the polar angles, and the time delay. Their widths determine six parameters: the coherence angles and coherence time, and the entanglement angles and entanglement time. We show how these parameters are governed by the pump-beam waist, the pump spectral width, and the crystal length. We thereby derive relations analogous to the van Cittert--Zernike theorem and the Siegert relation for thermal light. We show that the normalized photon coincidence rate decreases sharply as the signal and idler apertures become mismatched or misaligned. We experimentally confirm this latter prediction by using parametrically down-converted light obtained from a ${\mathrm{LiIO}}_{3}$ crystal pumped by ${\mathrm{Kr}}^{+}$-ion laser radiation at 413 nm. \textcopyright{}1996 The American Physical Society.
22
The Quantum Theory of Optical Coherence
Roy J. Glauber · Physical Review · 1963 · 4K citations · Full text
Natural Sciences, Physics, Optics +16
Bell inequality for position and time
J. D. Franson · Physical Review Letters · 1989 · 1.2K citations
Natural Sciences, Physics, Optics +14
Theory of parametric frequency down conversion of light
L. Mandeļ · Physical review. A, General physics · 1985 · 462 citations
Natural Sciences, Physics, Optics +15