British Journal of Dermatology · 2007 · 56 citations · 24 references
MedicineCardiologyDermatologyAllergyHypersensitivityInterventional CardiologyAllergen ExposureAllergic Skin DiseasesContact DermatitisCoronary Artery DiseasePatch TestingPercutaneous Coronary InterventionCoronary Stent RestenosisCoronary StentingMetal Allergy TestingMetal HypersensitivityMetal-induced DermatitisNickel Allergic Contact DermatitisRestenosis After StentingSensitization
BACKGROUND: Stent implantation is an effective method for treatment of atherosclerotic disease. Factors predisposing to in-stent restenosis are still largely unknown. Contact allergy to metal ions eluted from the stent has been suggested to be a risk factor. OBJECTIVES: To explore whether there is a possible induction of contact allergy to metals used in stents among patients with a stainless steel stent containing nickel (Ni stent) and patients with a gold-plated stent (Au stent). METHODS: Adults (n = 484) treated with coronary stent implantation participated in the study with patch testing. The study design was retrospective and cross-sectional with no assessment of contact allergy before stenting. Age- and sex-matched patch-tested patients with dermatitis (n = 447) served as controls. RESULTS: Of Au-stented patients, 54 of 146 (37%) were allergic to gold compared with 85 of 447 (19%) controls (P < 0.001). Within the stented population there were no statistically significant differences in contact allergy to gold or nickel between Ni-stented and Au-stented patients. In multivariate models where other risk factors for contact allergy to gold were considered, the Au stent showed a trend towards statistical significance (odds ratio 1.43, 95% confidence interval 0.95-2.16; P = 0.09). CONCLUSIONS: As the frequency of contact allergy to gold is higher in stented patients independent of stent type it suggests a previous sensitization. However, several pieces of circumstantial evidence as well as statistical analysis indicate the possibility of sensitization in the coronary vessel by the Au stent. Ni stents and Au stents should not be ruled out as risk factors for induction of contact allergy to these metals.
24
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Gregg W. Stone, Stephen G. Ellis, David A. Cox et al. · New England Journal of Medicine · 2004 · 2.7K citations · Full text
Medicine, Cardiology, Surgery +14
Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis
Ralf Köster, Dieter Vieluf, Margret Kiehn et al. · The Lancet · 2000 · 530 citations
Medicine, Cardiology, Immunology +14
Tissue-biomaterial interactions
David F. Williams · Journal of Materials Science · 1987 · 316 citations
In Vitro Analyses of Diamond-like Carbon Coated Stents
K. Gutensohn, C. Beythien, J. Bau et al. · Thrombosis Research · 2000 · 277 citations
Periodontal Infections and Coronary Heart Disease
Axel Spahr, Elena Klein, Natalie Khuseyinova et al. · Archives of Internal Medicine · 2006 · 249 citations