Journal of Petroleum Technology · 1976 · 16 citations · 0 references
EngineeringMining EngineeringReservoir CharacterizationReservoir EngineeringWater Resources EngineeringFormation TestingPolymer CharacterizationPolymer FloodingReservoir Quality AssessmentBiopolymer FloodingInjection TestingInjectivityPolymer-reservoir InteractionWater InjectionWater Injection TestingWaterfloodingWellbore Performance
Polymer injection and filtration field tests being carried out inthe East Coalinga field have been used to determine the degree ofin-situ mobility control and to furnish measurements and determine the nature of wellbore impairment. These tests also have been usedto develop criteria for describing solution quality using polyacrylamideand two grades of biopolymer. Introduction Water and polymer field-injection tests are beingconducted to furnish data for a planned pilot projectin the Temblor Zone II reservoir in the East Coalingafield, Calif. The pilot project will evaluate therelative merits of polymer flooding and waterflooding.A waterflood would have an unfavorable mobility ratioof 14.0, but this could be reduced to 1.5 with polymerflooding. Fig. 1 is an index map of the Coalinga fieldshowing the pilot project area.To choose the most suitable polymer for this project, it was necessary to determine the injection characteristicsof both polyacrylamide polymer and biopolymers. Theinjection field tests were supported by field filtrationtests and laboratory studies to define polymer viscosityand filtration properties. The field tests consistedof injecting both polymer solutions and pure water atdifferent times for periods of weeks to generate comparison data for polymer and water for determining thedegree of in-situ mobility control and possible wellboreimpairment. Polyacrylamide Injectivity Test Polyacrylamide polymer (Pusher 700) was originallyselected for field testing at the Coalinga field because, at the time of the test, more was known about thispolymer. To achieve maximum mobility control usingpolyacrylamide, and because it was readily available, afresh-water (300-ppm NACI) source was developed forthe project. This water caused severe wellbore damage (20-fold decrease in permeability) from clay swellingand dispersion during initial water-injection testing;therefore, the test well was chemically treated with theDarley treatment to prevent this damage.The properties of the unconsolidated sand and thefluids involved with the tests are as follows: Property Hx Sand Jv Sand Dept, ft 1,660 1,750Thickness ft 8 17Permeability, md 470 230water at Sor, md 165 80Porosity 0.28 0.28Oil gravity, deg.API 20 20 20Reservoirtemperature, deg.F 100 100Oil viscosityat reservoirtemperature, cp 25.0 25.0Water viscosityat reservoirtemperature, cp 0.64 0.64 The injection system for the polyacrylamide testwas carefully designed to prevent mechanical shear oroxygen degradation of the polymer at the surface. Fig.2 is a plot of water and polymer injectivity vs cumulative injection. JPT P. 586^