Medical Physics · 2012 · 20 citations · 28 references
MedicineCardiologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyCardiac ImagingCardiovascular ImagingComputed TomographyMedical ImagingMyocardial Perfusion ImagingPerfusion ImagingCardiac Computed TomographyEx Vivo ImagingIn Vivo ImagingIterative Image ReconstructionIterative ReconstructionMotion Artifact CorrectionPerfusion Computed TomographyQuantitative Cardiac Imaging
PURPOSE: Mouse models of cardiac diseases have proven to be a valuable tool in preclinical research. The high cardiac and respiratory rates of free breathing mice prohibit conventional in vivo cardiac perfusion studies using computed tomography even if gating methods are applied. This makes a sacrification of the animals unavoidable and only allows for the application of ex vivo methods. METHODS: To overcome this issue the authors propose a low dose scan protocol and an associated reconstruction algorithm that allows for in vivo imaging of cardiac perfusion and associated processes that are retrospectively synchronized to the respiratory and cardiac motion of the animal. The scan protocol consists of repetitive injections of contrast media within several consecutive scans while the ECG, respiratory motion, and timestamp of contrast injection are recorded and synchronized to the acquired projections. The iterative reconstruction algorithm employs a six-dimensional edge-preserving filter to provide low-noise, motion artifact-free images of the animal examined using the authors' low dose scan protocol. RESULTS: The reconstructions obtained show that the complete temporal bolus evolution can be visualized and quantified in any desired combination of cardiac and respiratory phase including reperfusion phases. The proposed reconstruction method thereby keeps the administered radiation dose at a minimum and thus reduces metabolic inference to the animal allowing for longitudinal studies. CONCLUSIONS: The authors' low dose scan protocol and phase-correlated dynamic reconstruction algorithm allow for an easy and effective way to visualize phase-correlated perfusion processes in routine laboratory studies using free-breathing mice.
28
David L. Donoho · IEEE Transactions on Information Theory · 2006 · 23.1K citations
Bilateral filtering for gray and color images
Carlo Tomasi, Roberto Manduchi · 2002 · 8.1K citations
Arts, Vision Science, Color Vision +16
L.A. Feldkamp, L. C. Davis, J. W. Kress · Journal of the Optical Society of America A · 1984 · 6.2K citations
Leif Østergaard, Robert M. Weisskoff, David A. Chesler et al. · Magnetic Resonance in Medicine · 1996 · 1.5K citations
Retro-orbital injections in mice
Tal Yardeni, Michael Eckhaus, H Douglas Morris et al. · Lab Animal · 2011 · 541 citations