Journal of The Electrochemical Society · 1973 · 25 citations · 0 references
Natural SciencesChemistryMaterials ScienceAnalytical ChemistryChemical KineticsElectrochemistryElectrochemical KineticsElectrode KineticsElectrode-electrolyte InterfacesElectrolyte MaterialsElectrolyte SolutionsIon Transport In ElectrolytesCharge Transfer KineticsCopper DepositionCopper KineticsDiffusion Coefficient CalculationDiffusion CoefficientsElectrolytesExchange Current DensityIonic Diffusion Coefficients
Measured l imiting currents iL for the deposition of copper on a platinum rotated disk electrode (RDE) were used to calculate the diffusion coefficients of copper ions in high-purity aqueous copper sulfate and copper fluoborate electrolytes. The diffusion coefficient in a 0.100M CuSO4/1.0M H2SO4 electrolyte was found to be 5.23-+- 0.13 X 10-6 cmf/sec, while the diffusion coefficient in a 0.072M Cu(BF4)2/1.0M HBF4 electrolyte was found to be 9.88 _ 0.05 • 10-6 cm2/sec. The values of iL were found to be directly proportional to the square root of the disk rotational rate ~,, as predicted by theory. Consistent correlations between the kinetic parameters controlling copper depositions and the con-centration of addition agents were found for copper fluoborate electrolytes containing Cubath Hy, z thiourea, and gelatin. General ly both the transfer coefficients (ar and the exchange current densities (io) were found to decrease with increasing concentrations of additives, in accord with the hypothesis that additives retard pr imary charge transfer and the rate of copper deposition.