Journal of Magnetic Resonance Imaging · 2012 · 33 citations · 22 references
MedicinePhysiologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyDiffusing CapacityLung VolumesPulmonary ImagingPulmonary Nuclear ImagingPulmonary PhysiologyRespiratory PhysiologyDiffusion MeasurementsDiffusive TransportGradient Echo ContrastGradient Echo SequencesInversion Recovery PulsesLung Volume AssessmentLung Volume QuantificationSaturation Inversion
PURPOSE: To implement and characterize a single-breath xenon transfer contrast (SB-XTC) method to assess the fractional diffusive gas transport F in the lung: to study the dependence of F and its uniformity as a function of lung volume; to estimate local alveolar surface area per unit gas volume S(A)/V(Gas) from multiple diffusion time measurements of F; to evaluate the reproducibility of the measurements and the necessity of B(1) correction in cases of centric and sequential encoding. MATERIALS AND METHODS: In SB-XTC three or four gradient echo images separated by inversion/saturation pulses were collected during a breath-hold in eight healthy volunteers, allowing the mapping of F (thus S(A)/V(Gas)) and correction for other contributions such as T(1) relaxation, RF depletion and B(1) inhomogeneity from inherently registered data. RESULTS: Regional values of F and its distribution were obtained; both the mean value and heterogeneity of F increased with the decrease of lung volume. Higher values of F in the bases of the lungs in supine position were observed at lower volumes in all volunteers. Local S(A)/V(Gas) (with a mean ± standard deviation of S(A)/V(Gas) = 89 ± 30 cm(-1)) was estimated in vivo near functional residual capacity. Calibration of SB-XTC on phantoms highlighted the necessity for B(1) corrections when k-space is traversed sequentially; with centric ordering B(1) distribution correction is dispensable. CONCLUSION: The SB-XTC technique is implemented and validated for in vivo measurements of local S(A)/V(Gas).
22
Biological magnetic resonance imaging using laser-polarized 129Xe
Mitchell S. Albert, G. D. Cates, Bastiaan Driehuys et al. · Nature · 1994 · 1K citations
Regional distribution of ventilation and perfusion as a function of body position.
Katsumi Kaneko, J Milic-Emili, Myrna Dolovich et al. · Journal of Applied Physiology · 1966 · 454 citations
Medicine, Anatomy, Physiology +13
Alveolar volume-surface area relation in air- and saline-filled lungs fixed by vascular perfusion
J. Gil, H Bachofen, Peter Gehr et al. · Journal of Applied Physiology · 1979 · 341 citations
Medicine, Anatomy, Pulmonology +15
High-volume production of laser-polarized 129Xe
Bastiaan Driehuys, G. D. Cates, E. Miron et al. · Applied Physics Letters · 1996 · 338 citations
Engineering, Nuclear Engineering, Nuclear Instrumentation +14