Radiology · 2011 · 74 citations · 43 references
MedicineAnatomyRadiologyDiagnostic ImagingPulmonary Function TestingPulmonologyPulmonary AnatomyPulmonary Function AssessmentPulmonary ImagingPulmonary Parenchymal ImagingPulmonary PathologyRespiratory DiseaseAcinar StructureAlveolar AnatomyEmphysema QuantificationForced Expiratory Volume AssessmentLung Function TestingLung Volume AssessmentLung Volume QuantificationQuantitative Lung Imaging
PURPOSE: To quantitatively characterize early emphysematous changes in the lung microstructure of current and former smokers with noninvasive helium 3 ((3)He) lung morphometry and to compare these results with the clinical standards, pulmonary function testing (PFT) and low-dose computed tomography (CT). MATERIALS AND METHODS: This study was approved by the local institutional review board, and all subjects provided informed consent. Thirty current and former smokers, each with a minimum 30-pack-year smoking history and mild or no abnormalities at PFT, underwent (3)He lung morphometry. This technique is based on diffusion MR imaging with hyperpolarized (3)He gas and yields quantitative localized in vivo measurements of acinar airway geometric parameters, such as airway radii, alveolar depth, and number of alveoli per unit lung volume. These measurements enable calculation of standard morphometric characteristics, such as mean linear intercept and surface-to-volume ratio. RESULTS: Noninvasive (3)He lung morphometry was used to detect alterations in acinar structure in smokers with normal PFT findings. When compared with smokers with the largest forced expiratory volume in 1 second (FEV(1)) to forced vital capacity (FVC) ratio, those with chronic obstructive pulmonary disease had significantly reduced alveolar depth (0.07 mm vs 0.13 mm) and enlarged acinar ducts (0.36 mm vs 0.3 mm). The mean alveolar geometry measurements in the healthiest subjects were in excellent quantitative agreement with literature values obtained by using invasive techniques (acinar duct radius, 0.3 mm; alveolar depth, 0.14 mm at 1 L above functional residual capacity). (3)He lung morphometry depicted greater abnormalities than did PFT and CT. No adverse events were associated with inhalation of (3)He gas. CONCLUSION: (3)He lung morphometry yields valuable noninvasive insight into early emphysematous changes in alveolar geometry with increased sensitivity compared with conventional techniques.
43
AN ESSAY TOWARDS SOLVING A PROBLEM IN THE DOCTRINE OF CHANCES
BAYES · Biometrika · 1958 · 2.9K citations
The National Lung Screening Trial: Overview and Study Design
Radiology · 2010 · 1.3K citations
N L Müller, C A Staples, Roberta R. Miller et al. · CHEST Journal · 1988 · 798 citations
The Number of Alveoli in the Human Lung
Matthias Ochs, Jens Randel Nyengaard, Anja Jung et al. · American Journal of Respiratory and Critical Care Medicine · 2003 · 761 citations
Medicine, Anatomy, Physiology +15
Morphometry of the human pulmonary acinus
Beatrice Haefeli‐Bleuer, Ewald R. Weibel · The Anatomical Record · 1988 · 668 citations
Medicine, Anatomy, Physiology +17