Concepedia

Publication | Open Access

A Safety and Efficacy Evaluation of Hemoglobin-Based Oxygen Carrier HBOC-201 in a Randomized, Multicenter Red Blood Cell Controlled Trial in Noncardiac Surgery Patients

41

Citations

21

References

2014

Year

Abstract

Up to 7 units of HBOC-201 infused over the course of 6 days resulted in RBC transfusion avoidance in 43% of patients. There were no notable differences in mortality and serious AEs incidence. The use of HBOC-201 was associated with a notable excess of nonserious AEs.

References

YearCitations