Journal of Cardiovascular Magnetic Resonance · 2009 · 63 citations · 23 references
Veterinary MedicineCardiologyBiomedical ImagingDiagnostic ImagingFlow VisualizationCardiac ImagingCardiovascular ImagingHemodynamicsBlood FlowBlood Flow MeasurementCardiac Flow QuantificationFlow Velocity MeasurementsMagnetic Resonance Flow QuantificationVelocityVelocity MappingVolumetric Flow Measurement
BACKGROUND: Two-dimensional, unidirectionally encoded, cardiovascular magnetic resonance (CMR) velocity mapping is an established technique for the quantification of blood flow in large vessels. However, it requires an operator to correctly align the planes of acquisition. If all three directional components of velocity are measured for each voxel of a 3D volume through the phases of the cardiac cycle, blood flow through any chosen plane can potentially be calculated retrospectively. The initial acquisition is then more time consuming but relatively operator independent. AIMS: To compare the curves and volumes of flow derived from conventional 2D and comprehensive 3D flow acquisitions in a steady state flow model, and in vivo through planes transecting the ascending aorta and pulmonary trunk in 10 healthy volunteers. METHODS: Using a 1.5 T Phillips Intera CMR system, 3D acquisitions used an anisotropic 3D segmented k-space phase contrast gradient echo sequence with a short EPI readout, with prospective ECG and diaphragm navigator gating. The 2D acquisitions used segmented k-space phase contrast with prospective ECG and diaphragm navigator gating. Quantitative flow analyses were performed retrospectively with dedicated software for both the in vivo and in vitro acquisitions. RESULTS: Analysis of in vitro data found the 3D technique to have overestimated the continuous flow rate by approximately 5% across the entire applied flow range. In vivo, the 2D and the 3D techniques yielded similar volumetric flow curves and measurements. Aortic flow: (mean +/- SD), 2D = 89.5 +/- 13.5 ml & 3D = 92.7 +/- 17.5 ml. Pulmonary flow: 2D = 98.8 +/- 18.4 ml & 3D = 94.9 +/- 19.0 ml). Each in vivo 3D acquisition took about 8 minutes or more. CONCLUSION: Flow measurements derived from the 3D and 2D acquisitions were comparable. Although time consuming, comprehensive 3D velocity acquisition could be relatively operator independent, and could potentially yield information on flow through several retrospectively chosen planes, for example in patients with congenital or valvular heart disease.
23
SENSE: Sensitivity encoding for fast MRI
Klaas P. Pruessmann, Markus Weiger, Markus B. Scheidegger et al. · Magnetic Resonance in Medicine · 1999 · 6.1K citations
Asymmetric redirection of flow through the heart
Philip J. Kilner, Guang‐Zhong Yang, Anna Wilkes et al. · Nature · 2000 · 708 citations
Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation
Joachim Lotz, Christian Meier, Andreas Leppert et al. · Radiographics · 2002 · 659 citations
Medicine, Cardiology, Radiology +16
Phase contrast cine magnetic resonance imaging.
Norbert J. Pelc, Robert J. Herfkens, Ann Shimakawa et al. · PubMed · 1991 · 608 citations
Medicine, Cardiology, Radiology +17