Physics in Medicine and Biology · 2013 · 231 citations · 17 references
MedicineRadiation OncologyRadiologyDiagnostic ImagingDiagnostic RadiologyTreatment PlanningComputed TomographyMagnetic Resonance ImagingMedical Image AnalysisMedical Image FormationMedical ImagingNeck Imaging3D Magnetic Resonance ImagingFunctional MriImage Contrast EvaluationProbabilistic ClassificationRadiology Image AnalysisStructural MriSynthetic Tissue ModelsT2-weighted Imaging
Magnetic resonance (MR) images often provide superior anatomic and functional information over computed tomography (CT) images, but generally are not used alone without CT images for radiotherapy treatment planning and image guidance. This study aims to investigate the potential of probabilistic classification of voxels from multiple MRI contrasts to generate synthetic CT ('MRCT') images. The method consists of (1) acquiring multiple MRI volumes: T1-weighted, T2-weighted, two echoes from a ultra-short echo time (UTE) sequence, and calculated fat and water image volumes using a Dixon method, (2) classifying tissues using fuzzy c-means clustering with a spatial constraint, (3) assigning attenuation properties with weights based on the probability of individual tissue classes being present in each voxel, and (4) generating a MRCT image volume from the sum of attenuation properties in each voxel. The capability of each MRI contrast to differentiate tissues of interest was investigated based on a retrospective analysis of ten patients. For one prospective patient, the correlation of skull intensities between CT and MR was investigated, the discriminatory power of MRI in separating air from bone was evaluated, and the generated MRCT image volume was qualitatively evaluated. Our analyses showed that one MRI volume was not sufficient to separate all tissue types, and T2-weighted images was more sensitive to bone density variation compared to other MRI image types. The short echo UTE image showed significant improvement in contrasting air versus bone, but could not completely separate air from bone without false labeling. Generated MRCT and CT images showed similar contrast between bone and soft/solid tissues. These results demonstrate the potential of the presented method to generate synthetic CT images to support the workflow of radiation oncology treatment planning and image guidance.
17
N4ITK: Improved N3 Bias Correction
Nicholas J. Tustison, Brian Avants, Philip A. Cook et al. · IEEE Transactions on Medical Imaging · 2010 · 6.4K citations
Medicine, Neuroscience, Radiology +16
Simple proton spectroscopic imaging.
W. Thomas Dixon · Radiology · 1984 · 2.3K citations
MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences
Vincent Keereman, Yves Fierens, Tom Broux et al. · Journal of Nuclear Medicine · 2010 · 436 citations