Concepedia

Publication | Closed Access

Identification of Neonatal Hearing Impairment: Distortion Product Otoacoustic Emissions during the Perinatal Period

90

Citations

49

References

2000

Year

Abstract

DPOAE measurements in neonates and infants result in robust responses in the vast majority of ears for f2 frequencies of at least 2.0, 3.0 and 4.0 kHz. SNRs decrease as frequency decreases, making the measurements less reliable at 1.0 kHz. When considered along with test time, there may be little justification for including an f2 frequency at 1.0 kHz in newborn screening programs. It would appear that DPOAEs result in reliable measurements when tests are conducted in the environments in which babies typically are found. Finally, these data suggest that babies can be tested in those states of arousal that are most commonly encountered in the perinatal period.

References

YearCitations

Page 1