Journal of Applied Physiology · 2005 · 254 citations · 27 references
EducationKinesiologyPhysiologyExercise PhysiologyExercise TestingHuman PerformanceAerobic CapacityAerobic ExerciseCardiopulmonary Exercise TestingCycle Ergometer TestingExercise Tolerance AssessmentPhysical FitnessExercise Tolerance EvaluationMaximal Oxygen Uptake MeasurementMaximal Oxygen Uptake TestingRamp Test ProtocolStep Test ProtocolWork RateWork Rate AssessmentWork Rate Response
The VO₂ response to ramp incremental exercise often fails to show a plateau, making it difficult to confirm a true maximum VO₂. This study tested whether adding a step exercise at a higher work rate after a ramp test could establish the plateau criterion. Seven healthy men performed a 20 W/min ramp cycle to exhaustion, followed by a 5‑min recovery and a 5‑min step test at 105 % (or 95 %) of the ramp peak work rate, with breath‑by‑breath VO₂ measured and the last 15 s averaged for peak values. No plateau was observed in any test, yet VO₂ peaks were unchanged between ramp and step phases, indicating that the plateau criterion can be met by comparing VO₂ peaks at different work rates even when the response curves lack a plateau.
The O 2 uptake (V̇o 2 ) response to ramp incremental (RI) exercise does not consistently demonstrate plateau-like behavior at the limit of tolerance, and hence the requirements for a maximum V̇o 2 commonly are not met, despite apparent maximum effort. We sought to determine whether an appended step exercise (SE) test at a work rate greater than that achieved in a preceding ramp test would establish the plateau criterion. Seven healthy male adults performed RI cycle ergometry (20 W/min) to the limit of tolerance, followed by 5-min recovery (20 W) and then an SE test at 105% (RISE-105) of the final work rate (WR peak ) achieved during RI. Five of these subjects also performed an RI test followed by SE at 95% WR peak (RISE-95). V̇o 2 was measured breath by breath using a turbine and mass spectrometer. The average of the final 15 s of RI or SE was used to establish respective V̇o 2 peaks. When V̇o 2 peak was approached, a constant V̇o 2 value (e.g., a plateau) was not discernable during any RI or SE component of the tests. Although the WR peak [mean (SD)] was higher during the SE portion [359 W (SD 31)] than during the RI portion [341 W (SD 29)] of the RISE-105, the peak V̇o 2 was not different [SE, 4.30 l/min (SD 0.51); RI, 4.33 l/min (SD 0.52); P = 0.49; n = 7]. Similarly, in the RISE-95 test, WR peak was 310 W (SD 31) for the SE portion and 326 W (SD 32) for the RI portion, yet the peak V̇o 2 values were not different [SE, 4.12 l/min (SD 0.53); RI, 4.11 l/min (SD 0.48); P = 0.78; n = 5]. The lack of notable difference between the V̇o 2 peaks established at different WR peak values in our RISE protocols provides the plateau criterion for verification of maximum V̇o 2 in a single test session, even when the data response profiles do not themselves evidence a plateau.
27
Criteria for maximal oxygen uptake
Edward T. Howley, David R. Bassett, H Welch · Medicine & Science in Sports & Exercise · 1995 · 1.6K citations
Education, Kinesiology, Physiology +17
Idelle M. Weisman, R. Jorge Zeballos · American Heart Journal · 1976 · 1.2K citations
Muscular Exercise, Lactic Acid, and the Supply and Utilization of Oxygen
Archibald Vivian Hill, H. Lupton · QJM · 1923 · 997 citations
Metabolic and respiratory profile of the upper limit for prolonged exercise in man
David C. Poole, Susan A. Ward, Gerald W. Gardner et al. · Ergonomics · 1988 · 777 citations