IEEE Transactions on Industrial Electronics · 2015 · 184 citations · 32 references
EngineeringElectrical EngineeringElectric MachinesFault TolerancePower ElectronicsDrive SystemsElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesFault DetectionPermanent Magnet MachinesFault Tolerant OperationInverter SystemsMotor Fault ToleranceMulti-phase Synchronous MachinesPermanent Magnet Synchronous MachinesPermanent Magnet Synchronous Motor DrivesPermanent Magnet Synchronous MotorsTorque
Multiphase machines are well known for their fault-tolerant capability. Star-connected multiphase machines have fault tolerance in an open circuit. For an inverter switch short-circuit fault, it is possible to keep a smooth torque of a permanent magnet synchronous machine if the currents of the faulty phases are determined and their values are acceptable. This paper investigates fault-tolerant operations of an open-end five-phase drive, i.e., a multiphase machine fed with a dual-inverter supply. Inverter switch short-circuit fault is considered and handled with a simple solution. Original theoretical developments are presented. Simulation and experimental results validate the proposed strategy.
32