Concepedia

Publication | Closed Access

Changes in pupil size induced by phacoemulsification and posterior chamber lens implantation: Consequences for multifocal lenses

50

Citations

14

References

1996

Year

Abstract

Preoperative pupil size does not predict postoperative size with sufficient consistency to ensure a good match between pupil diameter and the zone sizes of multizone multifocal intraocular lenses.

References

YearCitations

Page 1