MedicineCardiologySurgeryInterventional CardiologyPediatric CardiologyRadiation SafetyAblation TherapyCatheter AblationPediatric ArrhythmiasPediatric Cardiac ElectrophysiologyPediatric Cardiac SurgeryPediatric Interventional CardiologyAblation SafetyAccessory Pathway AblationElectrophysiological StudyFluoroscopy-guided AblationPatent Foramen Ovale AnatomyRadiation Safety In ChildrenSurgical AblationThree-dimensional Electroanatomic Mapping
BACKGROUND: Fluoroscopic catheter ablation of cardiac arrhythmias in pediatric patients exposes the patients to the potential risk of radiation considering the sensitivity of this population and its longer life expectancy. We evaluated the feasibility, safety, and efficacy of accessory pathway (AP) ablation guided by CARTO3 electroanatomic mapping (EAM) system with both cryoenergy and radiofrequency (RF) energy in order to avoid x-ray exposure in pediatric patients. METHODS: We included 44 patients (mean age: 13.1 ± 3.3 years); nine of 44 presented concealed AP. An electrophysiological study with a three-dimensional EAM reconstruction was performed in every patient with a venous transfemoral direct right atrium approach or an arterial transfemoral retrograde approach to reach the mitral annulus. In two patients with left-sided AP, the ablation was performed via a patent foramen ovale. RESULTS: A total of 47 APs were present, left sided in 45% (21/47) of cases (15 lateral, one anterior, three posteroseptal, and two posterolateral) and right sided in 55% (26/47; one anterior, three anterolateral, one posterolateral, three lateral, five para-Hisian, 12 posteroseptal, and one anteroseptal). Ablation without the use of fluoroscopy was successfully performed in every patient (33 with RF and in 11 with cryoenergy). No complication occurred. At a mean follow-up of 16.0 ± 11.7 months, we observed seven recurrences, three of them successfully re-ablated without fluoroscopy. In one case cryoablation of a para-Hisian AP was ineffective in the long term. CONCLUSIONS: Three-dimensional EAM allowed a safe and effective fluoroless AP ablation procedure in a pediatric population both with RF and cryoenergy.
23
Ionizing Radiation in Cardiac Imaging
Thomas C. Gerber, J. Jeffrey Carr, Andrew E. Arai et al. · Circulation · 2009 · 490 citations · Full text
Medicine, Cardiology, Radiology +12
Prospective Assessment after Pediatric Cardiac Ablation:
George F. Van Hare, Harold S. Javitz, Dorit Carmelli et al. · Journal of Cardiovascular Electrophysiology · 2004 · 363 citations
Medicine, Cardiology, Pediatrics +15
Lucia Venneri, Francesco Rossi, Nicoletta Botto et al. · American Heart Journal · 2008 · 350 citations · Full text
Medicine, Cardiology, Oncology +17
John D. Kugler, David A. Danford, KRIS A. HOUSTON et al. · Journal of Cardiovascular Electrophysiology · 2002 · 298 citations
Medicine, Cardiology, Pediatrics +17