Spine · 1991 · 136 citations · 0 references
MedicineNeuroscienceNeurosurgeryNeuroanatomyNeurophysiologySpinal BiomechanicsNerve Conduction StudiesSpinal AnatomySpinal Cord AnatomySpinal Cord CompressionSpinal Cord FunctionSpinal Cord PhysiologyAcute Spinal Cord CompressionCompressionConductionElectrophysiologic EffectsExperimental Model TestingRoot FunctionSpinal CompressionSpinal Nerve Roots
A well-controlled experimental model for analysis of compression-induced functional changes of the porcine cauda equina is presented. The model allows for electrophysiologic investigation of a variety of neurophysiologic changes induced by nerve root deformation. At an acute pressure threshold of 50-75 mm Hg, changes in both afferent and efferent conduction are induced. With higher compression pressure, a differential recovery in afferent and efferent conduction is seen.