Dynamics of electron flow in extended planar-anode diode operating at 19 MV and 700 kA

T. W. L. Sanford, J.A. Halbleib, J. W. Poukey, George Thomas Baldwin, G.A. Carlson, W. A. Stygar, Gary A. Mastin, Timothy J. Sheridan, R. C. Mock, J.A. Alexander,

Journal of Applied Physics · 1990 · 24 citations · 8 references

Concepts

Abstract

The electron flow in a planar-anode diode having an extended anode-cathode gap operating on the HERMES III accelerator is characterized and compared with predictions of a computational model. The model combines a particle-in-cell code with Monte Carlo radiation transport. The comparisons confirm the model and show that the diode provides both a matched load and a versatile large-area source of γ rays for the study of nuclear radiation effects. Electrical and spatial parameters of the beam at the diode and the downstream radiation fields from a graphite target are presented as a function of the anode-cathode gap.