Journal of Cataract & Refractive Surgery · 1999 · 53 citations · 9 references
MedicineOphthalmologySurgeryClinical OptometryOphthalmic SurgeryRefractive SurgeryAstigmatism CorrectionCataract ManagementCataract SurgeryLens SurgeryOcular ImplantsPreoperative Refractive EvaluationCataract Surgery Astigmatism ManagementOptical KeratoplastyPolymethyl MethacrylatePostoperative AstigmatismPostoperative RefractionPostoperative Visual AcuitySurgical AstigmatismVisual Function Loss
A 57-year-old man experienced a decrease in visual function because of cataract formation. Corneal astigmatism was 13.4 diopters (D) because he had had a penetrating keratoplasty 27 years before. Cataract surgery was planned, and biometric data for toric intraocular lens (IOL) implantation were collected for the manufacture of a custom IOL. After phacoemulsification, a toric poly(methyl methacrylate) (PMMA) IOL of +19.0 D spherical and +12.0 D cylindrical power was implanted via a sclerocorneal tunnel incision. Three months postoperatively, corneal astigmatism was 14.3 D and best corrected visual acuity (BCVA), 20/25. Postoperative refraction (+1.5 -3.0 x 90) and BCVA remained stable for 7 months. No significant IOL rotation was observed. Implantation of a toric PMMA IOL corrected high corneal astigmatism. Toric IOL technology with high cylindrical power allows enhancement of IOL surgery.
9
Biometry of 7,500 Cataractous Eyes
Kenneth J. Hoffer · American Journal of Ophthalmology · 1980 · 427 citations
Curved Keratotomy Procedure for Congenital Astigmatism
U Merlin · Journal of Refractive Surgery · 1987 · 45 citations
Medicine, Ophthalmology, Surgery +12