Journal of Plasma and Fusion Research · 2005 · 24 citations · 24 references
Natural SciencesPhysicsAcousticsComputational AcousticsPlasma PhysicsHigh-temperature PlasmasMagnetized PlasmaPlasma SimulationCorrection Factor DerivationLangmuir ProbesMach NumberSpecific Heat Capacity
Mach probe with two collecting tips facing to the direction parallel and perpendicular to the plasma flow, named para-perp type one, is evaluated by using a directional Langmuir probe (DLP) in a fast owing plasma produced by an MPD (Magneto-Plasma-Dynamic) arcjet. We present simple formulas to determine an ion acoustic Mach number Mi from the ratio of collected ion saturation currents. The formulas and experimentally-obtained data are compared with Hutchinson’s simulation results which are calculated using a particle-in-cell(PIC) code in an unmagnetized plasma condition. [I.H. Hutchinson, Plasma Phys. Control. Fusion, 44 1953 (2002).] Good agreements are obtained among these data in both subsonic and supersonic plasma flows. Correction factor κ to determine Mi is presented under various conditions of Ti/Te and the specific heat ratio for ions γi.
24
The Theory of Collectors in Gaseous Discharges
H. M. Mott-Smith, Irving Langmuir · Physical Review · 1926 · 1.6K citations
Physics of Electric Propulsion
R. G. Jahn, F. A. Lyman · Journal of Applied Mechanics · 1969 · 837 citations · Full text