Plasma Physics and Controlled Fusion · 1996 · 23 citations · 11 references
Natural SciencesElectrical EngineeringPhysicsPlasma PhysicsRadiation DetectionRadiation MeasurementDetector TechnologyHigh-temperature PlasmasRadiation DetectorsX-ray DetectionX-ray DetectorsX-ray SpectroscopyDetectorsFiltersSi(pin) DetectorsSoft X-ray SpectroscopyTime ResolutionX-ray DiagnosticsX-ray Emission SpectroscopyX-ray Line Emission
Core electron temperature measurements have been performed in the large, high-current RFX reversed field pinch experiment (a = 0.46 m, R = 2 m, target plasma current = 2 MA) with the double filter technique. With this technique the soft x-ray emission is measured by two Si detectors, covered by different Be-filters, and viewing the same region of the plasma. By choosing the filters in such a way that only the emission from the continuum part of the spectrum is measured, the ratio of the two signals is a function of the highest electron temperature along the line of sight of the detectors. With this diagnostic, the electron temperature has been measured in RFX with a bandwidth of approximately 2 kHz. This allows the direct measurement, for the first time in a RFP on a single shot basis, of coherent oscillations, associated with relaxation events and showing under some conditions a sawtooth-like character. The measurements of electron temperature obtained with this method are in good agreement with those performed with other diagnostics.
11
RFX: an expected step in RFP research
G. Rostagni · Fusion Engineering and Design · 1995 · 157 citations
Engineering, Electrical Engineering, Microwave Engineering +1
H.A.B. Bodin · Nuclear Fusion · 1990 · 150 citations