Japanese Journal of Applied Physics · 2010 · 45 citations · 22 references
Natural SciencesMaterials EngineeringMaterials ScienceCrystal StructureNanomaterialsThin FilmsAmorphous MaterialsAmorphous SolidsX-ray CrystallographyX-ray DiffractionX-ray Photoelectron SpectroscopyX-ray SpectroscopyAmorphous CarbonCrystallite Size AnalysisCrystallite Size DeterminationNanocomposite FilmsNear-edge X-ray Absorption Fine Structure SpectroscopyX-ray Absorption Near Edge StructureX-ray Absorption SpectroscopyX-ray Diffraction Analysis
Ultrananocrystalline diamond (UNCD)/nonhydrogenated amorphous carbon (a-C) composite films were grown in vacuum using a coaxial arc plasma gun. From the X-ray diffraction measurement, the UNCD crystallite size was estimated to be 1.6 nm. This size is dramatically reduced from that (2.3 nm) of UNCD/hydrogenated amorphous carbon (a-C:H) composite films grown in a hydrogen atmosphere. The sp 3 /(sp 3 + sp 2 ) value, which was estimated from the X-ray photoemission spectrum, was also reduced to be 41%. A reason for it might be the reduction in the UNCD crystallite size. From the near-edge X-ray absorption fine-structure (NEXAFS) spectrum, it was found that the π * C=C and π * C≡C bonds are preferentially formed instead of the σ * C–H bonds in the UNCD/a-C:H films. Since the extremely small UNCD crystallites (1.6 nm) correspond to the nuclei of diamond, we consider that UNCD crystallite formation should be due predominantly to nucleation. The supersaturated condition required for nucleation is expected to be realized in the deposition using the coaxial arc plasma gun.
22