Journal Of Clinical Periodontology · 2009 · 88 citations · 42 references
DentistryDental Biomaterials ScienceDental MaterialsOrthopaedic BiomaterialsOrthopedic BiomaterialsBone Quality AssessmentBone Tissue EngineeringDental CeramicsImplant MaterialsOsseointegration MonitoringSurface Modification Of ImplantsBiomaterial ImplantsBone-implant Contact AssessmentBone-to-implant ContactImplant Surface DesignOsteoconductivityZirconiaZirconia ImplantsZirconia Materials
OBJECTIVE: The objective of this study was to screen candidate nano-technology-modified, micro-structured zirconia implant surfaces relative to local bone formation and osseointegration. MATERIALS AND METHODS: Proprietary nano-technology surface-modified (calcium phosphate: CaP) micro-structured zirconia implants (A and C), control micro-structured zirconia implants (ZiUnite), and titanium porous oxide implants (TiUnite) were implanted into the femoral condyle in 40 adult male New Zealand White rabbits. Each animal received one implant in each hind leg; thus, 20 animals received A and C implants and 20 animals received ZiUnite and TiUnite implants in contralateral hind legs. Ten animals/group were euthanized at weeks 3 and 6 when biopsies of the implant sites were processed for histometric analysis using digital photomicrographs produced using backscatter scanning electron microscopy. RESULTS: The TiUnite surface demonstrated significantly greater bone-implant contact (BIC) (77.6+/-2.6%) compared with the A (64.6+/-3.6%) and C (62.2+/-3.1%) surfaces at 3 weeks (p<0.05). Numerical differences between ZiUnite (70.5+/-3.1%) and A and C surfaces did not reach statistical significance (p>0.05). Similarly, there were non-significant differences between the TiUnite and the ZiUnite surfaces (p>0.05). At 6 weeks, there were no significant differences in BIC between the TiUnite (67.1+/-4.2%), ZiUnite (69.7+/-5.7%), A (68.6+/-1.9%), and C (64.5+/-4.1%) surfaces (p>0.05). CONCLUSION: TiUnite and ZiUnite implant surfaces exhibit high levels of osseointegration that, in this model, confirm their advanced osteoconductive properties. Addition of CaP nano-technology to the ZiUnite surface does not enhance the already advanced osteoconductivity displayed by the TiUnite and ZiUnite implant surfaces.
42
A Concordance Correlation Coefficient to Evaluate Reproducibility
Biometrics · 1989 · 8.7K citations
Enhanced functions of osteoblasts on nanophase ceramics
Thomas J. Webster · Biomaterials · 2000 · 1.3K citations
Natural Sciences, Materials Engineering, Materials Science +14