PURPOSE: To examine the silicone oil content in 5 brands of ophthalmic viscoelastic devices (OVDs). SETTING: Department of Ophthalmology, Central Hospital of Vasteras, Vasteras, Sweden. METHODS: Phacoemulsification with intraocular lens (IOL) implantation was performed in 250 patients. Five brands of OVD were used, each one in 50 procedures. From each brand, 5 separate batches, each consisting of 10 syringes, were used. The 250 samples from identical batches were sent for spectrophotometric analysis, and 250 samples were used during surgery. RESULTS: The silicone oil content varied significantly between the OVD brands. CONCLUSIONS: Silicone oil is a common contaminant in many OVDs. Ophthalmic viscosurgical devices with relatively low silicone oil content are available.