Biosensors and Bioelectronics · 2013 · 22 citations · 31 references
EngineeringImmunologyMaterials ScienceBiosensorsNanobiotechnologyNanomaterialsBiosensors For Immune DetectionElectrochemical BiosensorsElectrochemical Impedance SpectroscopyElectrochemical SensorsNanomaterial-based BiosensorsNanosensorsCell ActivationElectrochemical ImmunosensorsElectrochemical Impedance AnalysisElectrochemical Impedance MonitoringImmune Cell Activation MarkersNanomaterial-based ImmunosensorsNanomaterial-enabled BiosensorsNanoparticles
A rapid, easy assay for monitoring dynamics of T-cell activation should help to guide potential medical evaluation of immune responses or immunopathogenesis. Here, we report development of novel electrochemical cytosensors for dynamic analyses of T-cell activation markers on living cells. Gold nanoparticles-doped polyaniline nanofiber (Au/PANI-NFs) composite was greenly prepared by in situ one-step chemical inertness of PANI-NFs with gold nanoparticles to fabricate impedance-based electrochemical biosensors. Transmission electron micrographs indicated that the gold nanoparticles were uniformly anchored along with the structure of PANI-NF surface, displaying fibrillar morphology with a ~60 nm diameter. Au/PANI-NFs-based cytosensors coated with anti-CD Ab molecules could provide biomimetic interface for multiple immunosensing of T-cell surface activation markers (CD69, CD25, and CD71). The dual signal amplification of Au nanoparticle and PANI-NFs-based electrochemical impedance spectroscopic (EIS) measurements enabled the cytosensors considerably sensitive, with a detection limit of 1×10(4) cells/ml of activated T-cells. The activation-targeted cytosensors detected early, middle and late stages for expression of activation markers CD69, CD25, and CD71 at 8 h, 24 h, and 36 h, respectively, after concanvalin A stimulation of T cells. The quantitative results consisted with those derived from flow cytometric analysis. Furthermore, activation-targeted cytosensor allowed for dynamic analysis of the immune inhibition of T-cell activation by immune regulatory drug icariin (ICA). Thus, Au/PANI-NFs-based cytosensors offer simple and fast approach for non-destructive, quantitative evaluation of T-cell activation markers, with considerable specificity, reproducibility, and low background noise.
31
Probing the Cytotoxicity of Semiconductor Quantum Dots
Austin M. Derfus, Warren C. W. Chan, Sangeeta N. Bhatia · Nano Letters · 2003 · 3.4K citations · Full text
Cancer exome analysis reveals a T-cell-dependent mechanism of cancer immunoediting
Hirokazu Matsushita, Matthew D. Vesely, Daniel C. Koboldt et al. · Nature · 2012 · 1.3K citations · Full text
Medicine, Cancer Biology, Oncology +16