Formation of homogeneous field in a shielded superconducting solenoid for an MRI

V.E. Eregin, V. S. Kashikhin, A.A. Lipatnikov, Yu.P. Severgin, V. Shangin, N. Shatil

IEEE Transactions on Magnetics · 1992 · 11 citations · 2 references

Concepts

Abstract

Methods are proposed for homogenizing and shimming a high homogeneity solenoid with a magnetic shield. The methods make the shield design more accurate and the shim coils less complicated. The whole-body 0.5 T superconducting MRI (magnetic resonance imaging) magnet is designed to achieve a field homogeneity of 3 ppm in a 50 cm DSV. Its fringe field is less than 0.5 mT outside a radius of 5 m using 12 tons of iron.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

References

2