IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 2001 · 178 citations · 12 references
Natural SciencesMaterials EngineeringMaterials ScienceAcousticsMaterials PhysicsUltrasoundAcoustic MaterialsAcoustic MeasurementAcoustic Wave PropagationComposite MaterialsPhysical AcousticsUltrasonicsAcoustic ImpedanceAcoustic PropertiesAluminaMaterial Acoustic PropertiesTransducersUltrasonic AttenuationUltrasonic SpectroscopyUltrasonic Transducers
The acoustic properties of passive materials for ultrasonic transducers have been measured at room temperature in the frequency range from 25 to 65 MHz using ultrasonic spectroscopy. These materials include alumina/EPO-TEK 301 composites and tungsten/EPO-TEK 301 composites. Experimental results showed that the acoustic impedance of the composites monotonically increased with the volume fraction of the particle filler, which is in agreement with the Denavey model. The attenuation, however, peaked between 7 and 9% volume fraction of particle filler. For comparison, several other passive materials were also fabricated and measured. The results suggest that materials that possess a higher attenuation also appear to have a larger velocity dispersion.
12
Ultrasonic transducers for nondestructive testing
M.G. Silk, J.P. Weight · NDT International · 1985 · 228 citations