Publication | Open Access
Assessment of Patient and Occupational Dose in Established and New Applications of MDCT Fluoroscopy
49
Citations
17
References
2009
Year
The study revealed high effective patient doses, up to 235 mSv, mainly for relatively new applications such as CTF-guided radiofrequency ablations using MDCT, vertebroplasty, and percutaneous ethanol injections of tumors. Entrance doses were occasionally in the range of the warning level for deterministic skin effects but were always below the threshold for serious deterministic effects. The complexity of the procedure, expected benefits of the treatment, and general health state of the patient contribute to the justification of observed high effective patient doses.
| Year | Citations | |
|---|---|---|
Page 1
Page 1