Environmental Progress · 1992 · 14 citations · 2 references
EngineeringChemical EngineeringEnvironmental EngineeringEnvironmental ChemistryReaction EngineeringWater TreatmentCatalytic Reactor DesignOrganic Contaminant RemediationOrganic PollutantsVolatile Organic Compound ControlVolatile Organic CompoundsCatalyst Efficiency TestingIncomplete CombustionIncomplete Combustion ProductsOrganic Pollutant RemovalVoc Oxidation ChemistryVolatile Organic Compound PollutionVolatile Organic Compound RemovalVolatile Organic Compound Sampling
Abstract Wurtsmith Air Force Base is the site of an air‐stripping‐with‐emissions‐control system to remove volatile organic compounds (VOCs), chiefly trichloroethylene (TCE), from groundwater. The purpose of this study was to evaluate the performance of a fluidized‐bed catalytic oxidation unit for destroying halogenated organics with respect to catalyst bed temperature and operating time. The objectives included identification of any products of incomplete combustion formed and determination of the utility costs for the unit. Samples were collected over a period of ∼ 19 months with volatile organic sampling trains according to the Environmental Protection Agency (EPA) Method 30. Samples were taken at catalyst bed temperatures of 315, 370, 425, and 480°C. The results indicate that the incinerator was destroying the TCE with <97% efficiency when operated at ≥370°C. A conservative cost estimate for utilities was determined to be $0.36/1000 gal of water treated.
2