American Journal of Roentgenology · 2011 · 54 citations · 16 references
MedicineCardiologyRadiologyCardiothoracic RadiologyDiagnostic ImagingDiagnostic RadiologyCardiac CatheterizationCardiovascular ImagingComputed TomographyCoronary AngiographyCoronary Artery DiseaseCoronary Artery ImagingComputed Tomography Coronary AngiographyComputed Tomography Coronary AssessmentCoronary Artery Disease ImagingCoronary Ct AngiographyCoronary Lesion AssessmentCoronary Vascular ImagingInvasive Coronary AngiographyQuantitative Coronary Angiography
OBJECTIVE: We determined the effect of reduced 80-kVp tube voltage on the radiation dose and image quality of coronary CT angiography (CTA) in patients with a normal body mass index (BMI). SUBJECTS AND METHODS: A prospective, multicenter, multivendor trial was performed of 208 consecutive patients with a normal BMI (< 25 kg/m(2)) who had been referred for coronary CTA and did not have a history of coronary revascularization. Patients were randomized to 80-kVp imaging (n = 103) or 100-kVp imaging (n = 105). Three blinded readers graded interpretability and image quality. Study signal, noise, and contrast were also compared. RESULTS: Imaging with 80 kVp instead of 100 kVp was associated with 47% lower median radiation dose (median dose-length product, 62.0 mGy · cm [interquartile range, 54.0-123.3 mGy · cm] vs 117.0 mGy · cm [110.0-225.9 mGy · cm], respectively; 0.9 mSv [0.8-1.7 mSv] vs 1.6 mSv [1.4-3.2 mSv]; p < 0.001 for each) with no significant difference in interpretability (99% vs 99%; p = 0.99) or image quality (median score, 4.0 [interquartile range, 3.6-4.0] vs 4.0 [interquartile range, 3.8-4.0]; p = 0.20). Studies obtained using 80 kVp were associated with 27% increased signal (mean ± SD, 756 ± 157 vs 594 ± 105 HU; p < 0.001), 25% higher contrast (890 ± 156 vs 709 ± 108 HU; p < 0.001), and 50% greater noise (55 ± 15 vs 37 ± 12 HU; p < 0.001) with resultant 15% and 16% decreases in signal-to-noise (mean ± SD, 15 ± 5 vs 17 ± 5; p < 0.001) and contrast-to-noise (mean ± SD, 17 ± 6 vs 21 ± 5; p < 0.001) ratios, respectively. CONCLUSION: Coronary CTA using 80 kVp instead of 100 kVp was associated with a nearly 50% reduction in radiation dose with no significant difference in interpretability and noninferior image quality despite lower signal-to-noise and contrast-to-noise ratios. The use of 80-kVp tube voltage should be considered in dose-reduction strategies for coronary CTA of individuals with a normal BMI.
16
Matthew J. Budoff, David A. Dowe, James G. Jollis et al. · Journal of the American College of Cardiology · 2008 · 2.1K citations
Medicine, Cardiology, Radiology +14
Diagnostic Performance of Coronary Angiography by 64-Row CT
Julie M. Miller, Carlos Eduardo Rochitte, Marc Dewey et al. · New England Journal of Medicine · 2008 · 1.8K citations
Medicine, Cardiology, Radiology +16
Estimated Radiation Dose Associated With Cardiac CT Angiography
Jörg Hausleiter · JAMA · 2009 · 993 citations
Medicine, Cardiology, Radiology +17