Journal of the CardioMetabolic Syndrome · 2006 · 18 citations · 39 references
MedicinePeriodonticsBone MetabolismMechanobiologyOrthopaedic BiomaterialsBone BiomechanicsBone MechanicsBone Quality AssessmentBone Quantity AssessmentImplant BiomechanicsPeri-implant Tissue HealthBiomechanical Testing Of ImplantsBone Strain Around ImplantsBone-implant Contact AssessmentBone-to-implant ContactImplant StabilityImplant-bone InteractionMechanical StimulationPeri-implant Tissue Biomechanics
OBJECTIVES: To investigate whether controlled early loading enhances peri-implant bone mass and bone-to-implant contact. Low-frequency stimulation (3 Hz) and varying force amplitudes, causing varying strains, were applied in three guinea-pig series. MATERIAL AND METHODS: Three series of guinea-pigs received percutaneous TiO(2)-blasted implants in both tibiae. One week after implant installation, one implant was stimulated with a sinusoidally varying bending moment while the contra-lateral implant served as an unloaded control. Force amplitudes of 0.5, 1 and 2 N were applied on a 20-mm-long cantilever, resulting in strains of 133, 267 and 533 muepsilon, respectively, measured by a strain gauge bonded on the surface of the tibial bone at 1.3 mm from the implant's distal surface. Implant stability was followed by means of resonance frequency analysis. Bone-to-implant contact and bone mass [BM (%) bone occupied area fraction] were analysed histomorphometrically. RESULTS: A significant positive effect on the difference in bone mass at the stimulated vs. at the control side was observed in the distal half peri-implant marrow cavity for early mechanical stimulation at a frequency of 3 Hz (P<0.0001). An optimum was reached for the applied load, which causes a strain of approximately 267 muepsilon 1.3 mm from the implant. Implant stability gradually increased in time; no significant effect of early stimulation could be measured. CONCLUSIONS: The effect of early controlled mechanical stimulation on the peri-implant bone, in this cortical bone model, is strongly dependent on force amplitude/strain at low-frequency stimulation.
39
Normalizing mitochondrial superoxide production blocks three pathways of hyperglycaemic damage
Takeshi Nishikawa, Diane Edelstein, Xue Du et al. · Nature · 2000 · 4.3K citations
Heart Disease and Stroke Statistics—2006 Update
Thomas Thom, Nancy Haase, Wayne D. Rosamond et al. · Circulation · 2006 · 3.5K citations · Full text
The epidemiology of heart failure: The Framingham Study
Kalon K.L. Ho, Joan L. Pinsky, William B. Kannel et al. · Journal of the American College of Cardiology · 1993 · 2.3K citations
Bone “mass” and the “mechanostat”: A proposal
Harold M. Frost · The Anatomical Record · 1987 · 2.1K citations