British Journal of Sports Medicine · 1991 · 55 citations · 4 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryExercise TestingFunctional Movement AssessmentOrthopedicsKnee BiomechanicsKnee DisordersKnee InjuriesKnee RehabilitationLower Extremity Function AssessmentOrthopedic ExaminationAnterior Cruciate Ligament TestsAnterior Drawer TestingClinical Screening TestsJerk ParameterKnee Function AssessmentKnee Joint AssessmentLigament Laxity AssessmentLigament Laxity Evaluation
A prospective study was undertaken to compare the accuracy of the Lachman test, anterior drawer test and jerk test with the KT1000 knee arthrometer in patients with proven anterior cruciate ligament deficiency. The Lachman and anterior drawer tests were found to be the most accurate indicators of anterior cruciate ligament deficiency. The KT1000 knee arthrometer was found to be totally inaccurate, which precludes its use as an objective measure of anteroposterior laxity of the knee.
4
Instrumented measurement of anterior laxity of the knee.
Dale M. Daniel, Lawrence Malcom, Gary M. Losse et al. · Journal of Bone and Joint Surgery · 1985 · 750 citations