Journal of Nuclear Science and Technology · 2005 · 45 citations · 12 references
EngineeringEarth SciencesNuclear EngineeringNuclear PhysicsRadiation DosimetryRadiation MeasurementBackground Radiation MeasurementDosimetry InstrumentationNeutron DetectionNeutron Spectrum AnalysisAltitude MeasurementBonner Sphere SpectrometryNeutron Background MeasurementNeutron Energy SpectraNeutron Equivalent DoseNeutron Flux SpectrumNeutron Radiation AssessmentNeutron Spectrometry
To assess the natural background neutron dose rate in Japan, a series of measurements of the cosmic-ray induced neutron energy spectra and the neutron dose rates were carried out in the Mt. Fuji area (altitude: 40-3,700m) by means of a Bonner multi-sphere neutron spectrometer (Bonner Spectrometer: BS) and a commercially available neutron rem-counter. The following results were obtained: 1. The neutron energy spectra at each altitude were almost the same in their shapes.2. The total neutron fluence rate and the ambient dose equivalent H*(10) obtained by BS at sea level were estimated to be about 0.0075±0.00029cm−2.s−1 and 6.4+0.25nSv.h−1, respectively.3. It was confirmed that the neutron fluence rate and the dose rate varied with the altitude according to an exponential law, ~ exp(αZ), where α=0.00071±0.00002m−1 for the fluence rate and α=0.00070±0.00001 m−1 for the dose rate, respectively. These α-values were smaller than those obtained at high geomagnetic latitudes in other studies.
12