International Journal of Architectural Heritage · 2014 · 129 citations · 18 references
EngineeringCivil EngineeringFinite Element AnalysisStructural AnalysisStructural EngineeringDynamic Response AnalysisDynamic Structural ResponseModal AnalysisStructural AssessmentStructural MechanicsVibration AnalysisAmbient Vibration TestingFinite Element Modal AnalysisModal IdentificationModal Parameter EstimationModal Parameter IdentificationStructural Modal IdentificationSubspace IdentificationTuning
A wide program of structural assessment has been carried out by Politecnico di Milano on the historic bell tower of the church Chiesa Collegiata in Arcisate (Varese, northern Italy). Within this context, the first part of the article summarizes the results obtained from the application of the stochastic subspace identification method to ambient response data collected in two dynamic tests, carried out in June 2007 and June 2008. Next presented is the vibration-based methodology developed for the calibration of a three-dimensional finite element model of the tower, consisting in the successive application of systematic manual tuning, sensitivity analysis, and simple system identification algorithm.
18
Proceedings of the 15th International Modal Analysis Conference
Proc. Spie Vol. · 1997 · 681 citations