Generation of Hydrogen Gas as a Result of Drilling Within the Saturated Zone

Bruce N. Bjornstad, James P. McKinley, Todd O. Stevens, S.A. Rawson, James K. Fredrickson, Philip E. Long

Groundwater Monitoring & Remediation · 1994 · 40 citations · 7 references

Concepts

Abstract

Abstract Hydrogen gas was discovered within the steel casing above standing water in a percussion‐drilled borehole on the Hanlord Site in south‐central Washington state. In situ measurements of the borehole fluids indicated anoxic, low‐Eh (<‐400 mV) conditions. Ground water sampled from adjacent wells in the same formation indicated that the ground water was oxygenated. H 2 was generated during percussion drilling, due to the decomposition of borehole waters as a result of aqueous reactions with drilled sediment and steel from the drilling tools or casing. The generation of H 2 within percussion‐drilled boreholes that extend below the water table may be more common than previously realized. The ambient concentration of H 2 produced during drilling was limited by microbial activity within the casing‐resident fluids. H 2 was generated abiotically in the laboratory, whereby sterilized borehole slurry samples produced 100 times more H 2 than unsterilizcd samples. It appears that H 2 is metabolized by microorganisms and concentrations might be significantly greater if not for microbial metabolism.

References

7