Pediatric Pulmonology · 1992 · 10 citations · 7 references
MedicinePediatricsPhysiologyPediatric PulmonologyPulmonologyVentilationFlow-volume LoopsLung VolumesMechanical VentilationPulmonary MechanicsRespiratory PhysiologyMean Airway PressurePressure - Volume RelationshipPressure SwingsPressure-volume CurvesPressure-volume LoopsRespiratory Mechanics MeasurementRespiratory System ComplianceRespiratory System Mechanics
We measured respiratory flow, volume by integrated flow, and airway pressure in four mechanically ventilated infants. Compliance of the respiratory system (Crs) was measured by the multiple occlusion method. Airway occlusion and release were achieved by a balloon in an occlusion valve between the endotracheal tube and a pneumotachometer, all connected in series with the respirator circuit. Values of Crs varied greatly due to changes in mean airway pressure (MAP). The Crs increased with the elevation of MAP on some occasions and decreased on others. Values of Crs also varied corresponding to different occlusion pressures for individual levels of MAP. Thus Crs changed continuously, even within a single respiratory cycle. The observed variability in Crs was explained by the following mechanism: a pressure-volume (P-V) loop of tidal ventilation moves its position within the pressure-volume diagram and changes shape due to variations of the ventilator settings. In some infants the lungs were ventilated in the range of the linear portion of the P-V diagram while in others they may have been ventilated on the flattened portion. Some patients had convex expiratory P-V curves even with low pressure swings during tidal ventilation.
7
Passive respiratory mechanics in newborns and children.
England Sj, Bryan Ac · PubMed · 1984 · 249 citations
Medicine, Pediatrics, Physiology +17